Nachi Robotics EC06

The EC06 is a four-axis SCARA robot intended for assembly and handling work, offered in three versions with 500 mm, 600 mm or 700 mm maximum reach. Its J4 tip axis is hollow, so tubes and hoses can be routed through the axis to the tool. Motion ranges are ±140° on J1, ±150° on J2, a 200 mm stroke on J3 and ±360° on J4.

Source checked20/20 values · 2026-10-25Nachi RoboticsScara robot
Payload
6kg
Repeatability
±0.02mm
IP rating
IP20
Axes
4

Specification

1 source
Categoryscara robot
Operating temp min0 °C
Operating temp max40 °C

Joints

NameRange min (°)Range max (°)Max speed (°/s)
J1-140140420
J2-150150720
J3
J4-3603602,660

Motion range per axis

arc = published range
J1
-140° / 140°420°/s
J2
-150° / 150°720°/s
J4
720°2,660°/s

Quick answers

What is the payload of the Nachi Robotics EC06?
6 kg, per EC06 | Nachi Robotics Systems, Inc. (nachirobotics.com).
What is the repeatability of the Nachi Robotics EC06?
±0.02 mm, per EC06 | Nachi Robotics Systems, Inc. (nachirobotics.com).
How many axes does the Nachi Robotics EC06 have?
4, per EC06 | Nachi Robotics Systems, Inc. (nachirobotics.com).
What is the IP rating of the Nachi Robotics EC06?
IP20, per EC06 | Nachi Robotics Systems, Inc. (nachirobotics.com).

Study notes

  • Three models: EC06-5020-01 with 500 mm reach, EC06-6020-01 with 600 mm reach, EC06-7020-01 with 700 mm reach.
  • Rated payload is 3 kg; maximum payload is 6 kg.
  • Robot weight is 17 kg for the 500 mm and 600 mm models and 18 kg for the 700 mm model.
  • J1+J2 composite maximum velocity: 7120 mm/s (500 mm), 7850 mm/s (600 mm), 8580 mm/s (700 mm).
  • Standard cycle time: 0.39 s (500 mm), 0.40 s (600 mm), 0.42 s (700 mm).
  • Position repeatability X+ composite ±0.02 mm; J3 (Z) ±0.01 mm; J4 (θ) ±0.005°.
  • J3 upward/downward stroke is 200 mm with a maximum velocity of 1100 mm/s.
  • J4 tip axis has a hollow structure so tool tubes and hoses can be routed through it.
  • Axis 3 maximum pressing force 100 N.
  • Maximum static load torque 0.05 kg·m² (rated 0.01 kg·m²).
  • Air tubes: primary φ6×2 and φ4×2; secondary φ6×2 and φ4×2 without a built-in valve, or φ6×1 and φ4×5 with a built-in valve.
  • Application cables: 24 wires (15 wires + 9 wires); the specification table lists floor mounting, while the additional information block also lists cleanroom, floor, tabletop, wall and invert/ceiling mounting.

Safety

  • Operating ambient temperature must stay within 0 ~ 40 °C.
  • Ambient humidity 20 ~ 80% RH; dew and frost are not allowed.
  • Brakes are fitted only to J3; J1, J2 and J4 are supplied without brake.
  • Protection class is IP20.
  • Mounting condition in the specification table is floor.
↑↓ navigate↵ openesc close