AutomationDirect SV2A-2150

The SV2A-2150 is a SureServo2 AC servo drive rated 1.5 kW with a nominal input of 110/230 VAC in single- or three-phase configuration. It controls torque, velocity and position, using step/direction, CW/CCW, A/B quadrature, internal indexing, or analog torque and velocity commands. It has one RS-485 (RJ45) port running Modbus RTU or Modbus ASCII slave at up to 115.2k baud, plus 10 discrete inputs, 6 discrete outputs and two analog input and output channels.

Source checked10/10 values · 2026-10-26AutomationDirectServo drive
Rated power
1.5kW
IP rating
IP20
Weight
1.7237kg

Specification

2 sources
Categoryservo drive
Supply voltage110/230 VAC, 1 and 3-phase
Feedback24-bit (16777216 ppr)
Operating temp min0 °C
Operating temp max55 °C

Quick answers

How much does the AutomationDirect SV2A-2150 weigh?
1.7237 kg, per Servo Drive: Modbus RTU and ASCII, 1.5 kW, 110/230 VAC, 1 and 3-phase (PN# SV2A-2150) | AutomationDirect (automationdirect.com).
What is the IP rating of the AutomationDirect SV2A-2150?
IP20, per Servo Drive: Modbus RTU and ASCII, 1.5 kW, 110/230 VAC, 1 and 3-phase (PN# SV2A-2150) | AutomationDirect (automationdirect.com).

Study notes

  • Output type is SVPWM output.
  • Encoder output is provided in addition to encoder resolution of 24-bit (16777216 ppr).
  • Number of discrete input points: 10 (sinking/sourcing); number of discrete output points: 6 (sinking/sourcing).
  • Analog I/O: 2 input channels at +/- 10 VDC and 2 output channels at +/- 8 VDC.
  • Command signals: step and direction, CW/CCW, A/B quad, internal indexing (via discrete input and communication port), torque and velocity (via analog input).
  • Tuning modes: easy/auto (4 methods) and manual.
  • Configuration is done by software and keypad.
  • Intended for use with 1 kW and 1.5 kW systems.
  • Optional EtherNet/IP and Modbus TCP cards are available; these fieldbuses are not native to the drive.
  • Enclosure type is enclosed; mounting is panel mount.
  • Single-phase input current is 12.6 A at 110 VAC and 14.8 A at 230 VAC; three-phase input current is 8.1 A at 230 VAC.

Safety

  • Protection functions stated: overcurrent, overvoltage, undervoltage, over-temperature, regeneration error, overload, velocity/position error, encoder error, secondary encoder position error, communication error, short circuit.
  • Operating temperature rating is 0 to 55 deg C.
  • Enclosure rating is IP20.
  • UL Listed File # E198015; CE declaration and RoHS status Yes (see CE Doc); EU REACH document available.
  • UL Recognized File # None; UL Hazardous File # None; CSA File # None.
↑↓ navigate↵ openesc close