AutomationDirect DURApulse GS4-4175

The DURApulse GS4-4175 is an open-frame AC variable frequency drive in the GS4 series. It takes 460 VAC three-phase input and drives a 175 hp motor using SVC or V/Hz control, with an RS-485 port for Modbus RTU, Modbus ASCII and BACnet communication. Built-in Safe Torque Off is included, and an external dynamic braking unit is required.

Source checked10/10 values · 2026-10-26AutomationDirectVFD
Rated power
130.4975kW
Rated current
247A

Specification

2 sources
Categoryvfd
Supply voltage460 VAC
Frame sizeF
Output typePWM output
Operating temp min-10 °C
Operating temp max50 °C

Study notes

  • Series: GS4.
  • Input and output: 3 phases, 460 VAC nominal.
  • Variable torque amperage rating: 260 A.
  • Control mode: SVC or V/Hz.
  • Carrier frequency range: 2-15 kHz; output frequency range: 0.1-599 Hz.
  • Communication port: one RS-485 (RJ12) port at up to 115.2k baud; BACnet is listed but has no matching protocol id.
  • Input signal: 4-20 mA, voltage or potentiometer input.
  • Analog I/O: 3 analog inputs (11-bit) and 2 analog outputs (10-bit).
  • Discrete I/O: 8 discrete inputs (24 VDC, sinking/sourcing) and 4 relay/sinking/sourcing outputs (240 VAC and 48 VDC; 2 Form C relays).
  • Programming language: ladder; for use with 3-phase induction motors.
  • Optional EtherNet/IP and Modbus TCP cards are available.
  • Item shipping weight: 239 lb; mounting: panel or wall.

Safety

  • Built-in Safe Torque Off (STO).
  • External dynamic braking unit required.
  • User-supplied external fuse required.
  • IP rating: IP00 and IP20; enclosure type: open frame.
  • Operating temperature rating: -10 to +50 °C.
  • UL Listed File # E198015; CE; RoHS: Yes; EU REACH document available.
↑↓ navigate↵ openesc close