AutomationDirect GS4-22P0

The GS4-22P0 is a DURApulse GS4 series AC variable frequency drive rated for 230 VAC. It delivers 2 hp with a 3-phase input and 3/4 hp with a 1-phase input, using either sensorless vector control (SVC) or V/Hz control. It is built in a NEMA 1, IP20 enclosure with an A frame, has integrated dynamic braking, and communicates over RS-485.

Source checked8/8 values · 2026-10-26AutomationDirectVFD
IP rating
IP20

Specification

2 sources
Categoryvfd
Supply voltage230 VAC
Frame sizeA
Operating temp min-10 °C
Operating temp max50 °C

Quick answers

What is the IP rating of the AutomationDirect GS4-22P0?
IP20, per DURApulse AC High-performance Drive: 230 VAC, 2hp with 3-phase input, 3/4hp with 1-phase input, (VFD) (PN# GS4-22P0) | AutomationDirect (automationdirect.com).

Study notes

  • Supply and output voltage are both 230 VAC; input may be 3-phase or 1-phase, output is 3-phase.
  • Amperage rating is 7.1 A with 3-phase input and 3.2 A with 1-phase input; variable torque rating is 8 A.
  • Control mode is selectable between SVC (sensorless vector control) and V/Hz.
  • Carrier frequency range is 2-15 kHz; output frequency range is 0.1-599 Hz.
  • RS-485 port uses an RJ12 connection and supports speeds up to 115.2k baud.
  • Port protocols listed are Modbus RTU, Modbus ASCII and BACnet; BACnet has no matching reference id in this schema.
  • Optional EtherNet/IP and Modbus TCP cards are available and are not built in.
  • Integrated dynamic braking and built-in reverse capability are included; the drive is not internally bypassed and has no integrated EMI filter.
  • Analog I/O: 3 input channels (11-bit, 0-20 mA / 4-20 mA, +/-10 VDC) and 2 output channels (10-bit, 0-20 mA / 4-20 mA, 0-10 VDC).
  • Discrete I/O: 8 sinking/sourcing inputs at 24 VDC and 4 relay/sinking/sourcing outputs at 240 VAC or 48 VDC, rated 3 A/point relay and 50 mA/point discrete.
  • Programming language is ladder; GSLOGIC drive PLC software and GSOFT2 configuration software are listed for the series.
  • Intended for use with 3-phase induction motors; connector type is screw terminals and the fuse is user-supplied external.

Safety

  • Safe Torque Off (STO) is built-in.
  • UL Listed, file # E198015; UL Recognized and UL Hazardous file numbers are listed as none.
  • CE declaration available and RoHS status is Yes (see CE document); EU REACH document available.
  • Enclosure is NEMA 1 with IP20 rating, so it is not protected against water or dust ingress.
  • Operating temperature rating is -10 to +50 deg C; mounting is panel or wall.
↑↓ navigate↵ openesc close