AutomationDirect GS23-53P0

The GS23-53P0 is an enclosed DURApulse GS20 series general-purpose AC variable frequency drive rated 3 hp for 575 VAC three-phase input and output. It controls three-phase induction and permanent magnet AC motors using SVC, V/Hz, FOC or torque control modes, and includes integrated dynamic braking and built-in reverse. Setup and monitoring are done through RS-485 (RJ45) or USB B ports, and an optional EtherNet/IP and Modbus TCP card can be added.

Source checked9/9 values · 2026-10-26AutomationDirectVFD
IP rating
IP20

Specification

2 sources
Categoryvfd
Supply voltage575 VAC, 3-phase
Frame sizeC
Output typePWM output
Operating temp min-20 °C
Operating temp max50 °C

Quick answers

What is the IP rating of the AutomationDirect GS23-53P0?
IP20, per DURApulse AC General Purpose Drive: 575 VAC, 3hp with 3-phase input, (VFD) (PN# GS23-53P0) | AutomationDirect (automationdirect.com).

Study notes

  • Control modes: SVC, V/Hz, FOC or torque.
  • Rated current 4.2 A; variable torque rating 5 A; 3 hp with 3-phase input at 575 VAC.
  • Output frequency range 0.1-599 Hz; carrier frequency range 2-15 kHz.
  • RS-485 (RJ45) and USB B communication ports, speeds up to 115.2k baud, Modbus RTU Slave and Modbus ASCII Slave protocols.
  • 2 analog inputs (10-bit and 12-bit resolution; 0-20 mA, 4-20 mA, +/-10 VDC) and 1 analog output (10-bit; 0-20 mA, 4-20 mA, 0-10 VDC).
  • 7 discrete inputs at 24 VDC (sinking/sourcing) and 3 discrete outputs (relay/sinking/sourcing), one Form C (SPDT) relay; relay load 3 A/point, discrete 50 mA/point.
  • Programming language: ladder; spring clamp terminals.
  • Integrated EMI filter: no; internally bypassed: no.
  • Optional EtherNet/IP and Modbus TCP card available; not built in.
  • Agency approvals: UL Listed file E198015, CE, RoHS compliant; no UL Recognized, UL Hazardous or CSA file.
  • Item shipping weight 3.35 lb; country of origin Taiwan.

Safety

  • Safe Torque Off (STO) is built-in.
  • IP20 enclosure; temperature rating -20 to +50 deg C.
  • User-supplied external fuse required.
  • Intended for use with 3-phase induction and permanent magnet AC motors.
↑↓ navigate↵ openesc close