AutomationDirect GS11N-11P0

The GS11N-11P0 is an enclosed DURApulse GS10 series AC micro drive. It accepts 120 VAC single-phase input and provides 230 VAC three-phase output for a 1 hp motor. It uses SVC or V/Hz control, has integrated dynamic braking, and communicates over RS-485 using Modbus RTU or ASCII.

Source checked11/11 values · 2026-10-26AutomationDirectVFD
Rated power
0.7457kW
Rated current
4.8A
IP rating
IP20

Specification

2 sources
Categoryvfd
Supply voltage120 VAC
Frame sizeC1
Output typePWM output
Operating temp min-20 °C
Operating temp max50 °C

Quick answers

What is the IP rating of the AutomationDirect GS11N-11P0?
IP20, per DURApulse AC Micro Drive: 120 VAC, 1hp with 1-phase input, (VFD) (PN# GS11N-11P0) | AutomationDirect (automationdirect.com).

Study notes

  • GS10 series enclosed micro drive; controller type is Micro.
  • Input is 1-phase 120 VAC; output is 3-phase 230 VAC.
  • Horsepower rating is 1 hp with 1-phase input.
  • Variable-torque amperage rating is 5.5 A.
  • Control mode is SVC or V/Hz.
  • Integrated dynamic braking and built-in reverse capability; internally bypassed: No.
  • Integrated EMI filter: No.
  • RS-485 (RJ45) port supports Modbus RTU Slave and Modbus ASCII Slave up to 38.4k baud.
  • Analog input: 1 channel, 12-bit, 0-20 mA / 4-20 mA or 0-10 VDC. Analog output: 1 channel, 12-bit, 0-10 VDC.
  • Discrete inputs: 5 points at 24 VDC, sinking/sourcing. Discrete outputs: 2 relay/sinking/sourcing points rated 240 VAC and 48 VDC.
  • Load current: 3 A/point relay, 50 mA/point discrete.
  • Carrier frequency range is 2-15 kHz; output frequency range is 0.1-599 Hz. For use with 3-phase induction and permanent magnet AC motors.

Safety

  • UL Listed File # E198015. The document states no UL Recognized file, no UL Hazardous file, and no CSA file.
  • Safe Torque Off (STO): None.
  • A user-supplied external fuse is required.