AutomationDirect DURApulse GS11N-10P2

The GS11N-10P2 is an enclosed DURApulse GS10 series AC micro variable frequency drive. It takes single-phase 120 VAC input and produces three-phase 230 VAC output for a 1/4 hp motor, using either sensorless vector control (SVC) or V/Hz control mode. It provides RS-485 communication, analog and discrete I/O, spring clamp terminals, and integrated dynamic braking in an A1 frame.

Source checked8/8 values · 2026-10-26AutomationDirectVFD
IP rating
IP20

Specification

2 sources
Categoryvfd
Supply voltage120 VAC
Frame sizeA1
Operating temp min-20 °C
Operating temp max50 °C

Quick answers

What is the IP rating of the AutomationDirect DURApulse GS11N-10P2?
IP20, per DURApulse AC Micro Drive: 120 VAC, 1/4hp with 1-phase input, (VFD) (PN# GS11N-10P2) | AutomationDirect (automationdirect.com).

Study notes

  • Drive rating is 1/4 hp with 1-phase input; nominal output is 3-phase 230 VAC, 1.6 A rated and 1.8 A variable torque.
  • Control mode is SVC or V/Hz; carrier frequency range 2–15 kHz; output frequency range 0.1–599 Hz.
  • Communication is one RS-485 (RJ45) port running Modbus RTU Slave or Modbus ASCII Slave at up to 38.4k baud.
  • Discrete I/O: 5 inputs at 24 VDC (sinking/sourcing) and 2 outputs rated 240 VAC / 48 VDC (relay/sinking/sourcing), including one Form C (SPDT) relay; load current 3 A/point relay, 50 mA/point discrete.
  • Analog I/O: 1 input channel (0–20 mA and 4–20 mA current, 0–10 VDC voltage, 12-bit) and 1 output channel (0–10 VDC, 12-bit); input signal can also be a potentiometer.
  • Output type is PWM; reverse capability is built-in; dynamic braking is integrated and the drive is not internally bypassed.
  • Frame size A1, panel or wall mounting, spring clamp terminals, user-supplied external fuse required.
  • Intended for 3-phase induction and permanent magnet AC motors.
  • Configuration software is GSOFT2; firmware and sample PLC programs for GS10 drive control are available.
  • Shipping weight 2.15 lb; country of origin India.

Safety

  • No Safe Torque Off (STO) function is provided.
  • No integrated EMI filter.
  • Enclosure is IP20.
  • An external fuse must be user-supplied.
  • UL Listed, file # E198015; RoHS status Yes (see CE documentation).
  • Operating temperature rating -20 to +50 °C.
↑↓ navigate↵ openesc close