The KEYENCE CS-LC60PC is a linear cylinder sensor in the CS-L series. It uses a C-shaped slot and provides PNP open-collector output. It detects piston position magnetically with 0.1 mm resolution.

## Specification

| Property | Value |
|---|---|
| Category | sensor |
| Repeatability | 0.5 mm |
| Weight | 0.017 kg |
| Supply voltage | 18 to 30 VDC |
| Output type | PNP open-collector |
| Power consumption | 0.00065 kW |
| IP rating | IP65 |
| Operating temp min | -20 °C |
| Operating temp max | 60 °C |

## Connected

- Standards: [IEC 60529 Degrees of protection provided by enclosures (IP Code)](https://machineschema.com/standard/iec-60529.md)
- Manufacturer: [KEYENCE](https://machineschema.com/manufacturer/keyence.md)
- Protocols: [IO-Link](https://machineschema.com/protocol/io-link.md)

## Safety

- Ambient temperature range: -20 to +60°C (no freezing).
- Relative humidity: up to 85% RH (no condensation).
- Vibration resistance: 10 to 500 Hz, power spectral density 0.816 G²/Hz in X, Y, and Z directions.
- Shock resistance: 100 m/s² (10 G), 1000 times each for X, Y, and Z axes.
- Power supply must be Class 2 or LPS.
- Cable length must be 30 m or less for PNP M8 connector type; 20 m or less when using IO-Link.

## Study notes

- Sensor size: 60 mm; supported slot shape: C-shaped slot.
- Detection length: supported cylinder length + 5 mm.
- Minimum detectable magnetic flux density: 2 mT; maximum supported speed: 3 m/s.
- Resolution: 0.1 mm; repeatability: ±0.5 mm; detection cycle: 1 ms (default response time 3 ms).
- Display method: Bar LED.
- Number of outputs: 2 (sensor alone) or 4 (IO-Link/SP-N/V Series).
- Control output: open-collector, 30 VDC or less, 100 mA total for 2 outputs, residual voltage 2.5 V or less.
- Power consumption: 650 mW (27 mA or less at 24 V); protection: reverse polarity and output overcurrent.
- Network function: IO-Link (Specification v1.1/COM3).
- Impact monitoring function available.
- Material: polyamide, PBT, POM, SUS303, zinc nickel plating, NBR; weight approx. 17 g; enclosure rating IP65/IP67 (IEC 60529).
- Cable length limit: 30 m or less for PNP M8 connector type; 20 m or less for IO-Link.